2-Ton AC and Coil Installation in Frederick, MD
The existing outdoor condenser at this Frederick, MD property had settled into soft ground to the point where the unit was sinking in the mud — a problem that compromises refrigerant line connections, electrical components, and long-term equipment performance. The homeowner opted to replace the system entirely rather than attempt to salvage aging equipment in a deteriorating position.
Mychall removed the old condenser and evaporator coil and installed a Lennox Merit ML14KC1 2-ton single-stage air conditioner paired with a CK40CT 2.5-ton R-454B dedicated evaporator coil. The new condenser is rated at 14.3 SEER2 and 11.7 EER2, meeting current efficiency standards, and runs on R-454B refrigerant. The coil is an aluminum-cased upflow configuration matched to the indoor air handler. As part of the installation, Mychall addressed duct and drain modifications needed to properly integrate the new equipment, and the condenser was set on a stable pad to eliminate the settling issue that had compromised the previous unit.
With the new system in place, the homeowner has a properly supported, correctly sized cooling setup going into the season. The installation includes a 10-year parts warranty on the equipment and a 3-year labor warranty covering the installation work — two separate layers of protection. A maintenance agreement was also added at the time of installation to keep the new system running at rated efficiency.
Heat Pump System Installation in Frederick, Maryland
A homeowner in Frederick, Maryland was ready to replace their existing heating and cooling equipment with a new, more efficient system. The full replacement scope — outdoor unit, air handler, and electric heat kit — was planned in advance, with all components easily accessible for the installation crew.
Mychall installed a Lennox Merit ML14KP1 2.5-ton single-stage heat pump paired with a CBK45UHET air handler, both rated for R-454B refrigerant. The outdoor unit carries a 14.3 SEER2 efficiency rating and meets or exceeds a 7.5 HSPF2 heating efficiency threshold. A Lennox ECB45-7.5CB 7.5 kW electric heat kit with integrated circuit breaker was added to the air handler to handle supplemental heating demand. Existing equipment was removed as part of the same visit, and the installation included duct modifications, drain line updates, and a new thermostat to complete the system changeover.
With the new system in place, the homeowner has a properly sized, single-stage heat pump handling both heating and cooling from one integrated setup. The installation is backed by a 10-year parts warranty on the Lennox equipment and a 3-year labor warranty covering BPM’s work. The project also qualified for a Tier One rebate through the EmPower Maryland Utility Program for Potomac Edison, applied to the installation.
AC and Furnace System Installation in Frederick, MD
A homeowner in Frederick, MD was ready to replace their existing heating and cooling equipment with a full matched system. The project called for a new air conditioner, evaporator coil, and gas furnace — along with a new thermostat, duct modifications, and drain modifications to bring everything up to current standards.
Mychall installed a Merit ML14KC1 2-ton single-stage air conditioner paired with a CK40CT-24A-71 R-454B dedicated evaporator coil and a Merit ML180UH070E36AK 80% AFUE upflow gas furnace rated at 66,000 BTUh. The system is rated at 16.0 SEER2 and 13.4 EER2, meeting current efficiency requirements. The refrigerant is R-454B, the lower-GWP replacement now standard on new residential equipment. Existing equipment was removed as part of the installation. Duct and drain configurations were modified to suit the new system, and a new thermostat was installed to complete the setup. An Air Scrubber and Laundry Pro were added to the system on the same visit.
With the new matched system in place, the homeowner has reliable heating and cooling sized correctly for the home. The installation qualified for a Potomac Edison utility rebate, applied to the project. Equipment is covered by a 10-year parts warranty from the manufacturer. BPM’s labor warranty covers the installation for 3 years.
3-Ton AC and Coil Installation in Frederick, MD
The homeowner in Frederick, MD had been living with an air conditioner that couldn’t keep up — the system consistently fell short of set temperatures, and both the condenser and evaporator coil had reached the point where replacement made more sense than repair. With plans to sell the home within the year, the goal was a reliable, right-sized system that wouldn’t break the budget.
Mychall installed a Lennox Merit ML14KC1 3-ton single-stage air conditioner paired with a CK40CT dedicated evaporator coil — both rated for R-454B refrigerant. The system is rated at 14.3 SEER2 and 11.7 EER2, with a cooling capacity of 34,200 BTU. The existing outdoor unit and coil were removed as part of the installation. Mychall set a new outdoor pad, made duct modifications to support the new configuration, and updated the condensate drain routing. The matched coil is an aluminum-cased upflow unit, sized to work in step with the new condenser.
With the new 3-ton system in place, the home now has equipment properly matched to its cooling load — a direct fix for the temperature shortfall the homeowner had been dealing with. The installation carries a 10-year parts warranty on the equipment and a 3-year labor warranty covering the installation work itself, giving the homeowner solid coverage whether they’re still in the home or passing it along to a buyer.
HVAC System Replacement with Air Quality Upgrades in Frederick, MD
A homeowner in Frederick, MD had already done the research — they came to BPM through an online quote request and scheduled this appointment to confirm the scope and finalize the replacement plan. The existing heating and cooling system was at end of life, and the goal was a full matched-system swap with indoor air quality improvements added at the same time.
Mychall installed a Lennox Merit three-component system: a 3.5-ton ML14KC1 single-stage air conditioner rated at 16.5 SEER2, paired with an ML180UH090E48BK 80% AFUE upflow furnace at 88,000 BTU, and a CK40CT dedicated evaporator coil — all running on R-454B refrigerant. The installation included removal of the old equipment, duct and drain modifications, a secondary drain safety switch, and a new ecobee Wi-Fi thermostat. Alongside the core system, Mychall installed an Aprilaire 700M whole-home powered humidifier and an Air Scrubber unit, both integrated directly into the new system’s ductwork. Those additions were handled in the same visit rather than as separate service calls.
With the new system in place, the homeowner has a properly matched, efficiency-rated setup backed by a 10-year parts warranty on the equipment and a 3-year BPM labor warranty covering the installation. The project also qualified for a Potomac Edison utility rebate, applied to the project. The humidifier and air scrubber extend the system’s function beyond heating and cooling — addressing humidity balance and airborne contaminants throughout the home year-round.